CLASSIFICATION OF DISTRIBUTION TRANSFORMERS IN AN ELECTRICAL DISTRIBUTION SYSTEM

CLASSIFICATION OF DISTRIBUTION TRANSFORMERS IN AN ELECTRICAL DISTRIBUTION SYSTEMHow are distribution transformers being classified according to different parameters?

In dealing with distribution transformers, several parameters are always in consideration that describes the factors that a distribution transformer must have. Distribution transformers are classified into several different categories based on certain factors such as:

Image Detail

Type of Insulation used – distribution transformer insulation does not only ensures isolation of the transformer windings from other transformer parts (i.e. tank) but also serves as a coolant during rise of temperature. The transformer insulation can be liquid-immersed or dry-type. Liquid-immersed distribution transformers typically use oil to insulate the core and the windings. This oil can either be mineral or synthetic that should be non-flammable. Dry-type on the other hand uses gaseous or dry compound as an insulating medium.

Number of phases – depending on the nature of load that should be catered, a distribution transformer can be designed to serve either a single-phase or a three-phase load. Also, a single-phase transformer can also be used to serve a three-phase load by interconnecting 3-units of single-phase transformer or banked them to create a three-phase equivalent. However, a single unit three phase distribution transformer is also readily available if preferred by the utility or with the customer.

Voltage Class (for dry type) – The voltage class of a dry-type distribution transformer breaks down into two; low voltage distribution transformer or medium voltage distribution transformer. Voltage class of a distribution transformer depends on the desired secondary voltage while also considering the primary voltage where it would be connected. When specifying distribution transformers, manufacturers should know what voltage level a distribution transformer will be used.

Basic Impulse Insulation Level (BIL) - Outdoor electrical distribution systems are subject to lightning surges. Even if the lightning strikes the line some distance from the transformer, voltage surges can travel down the line and into the transformer. High voltage switches and circuit breakers can also create similar voltage surges when they are opened and closed. Both types of surges have steep wave fronts and can be very damaging to electrical equipment. To minimize the effects of these surges, the electrical system is protected by lighting arresters but they do not completely eliminate the surge from reaching the transformer. The basic impulse level (BIL) of the transformer measures its ability to withstand these surges. All 600 volt and below transformers are related 10 KV BIL. The 2400 and 4160 volt transformers are rated 25 KV BIL.

Transformer Location – the location of which the distribution transformer must be installed must also be considered. Indoor transformers are designed that this type of equipment must be protected from weather. An outdoor transformer has a construction designed to be weather resistant and suitable for varying weather service.

Comments

  1. Sri Sai Ram Power Controls as a manufacturer of Power Transformers, Distribution Transformers, Furnace Transformers and Dry type Transformers has been part of Transformer Industry in India.


    for more info
    http://www.saipowercontrols.in/

    ReplyDelete
  2. Thanks for sharing knowledge of transformers. I am working in a company of Transformer Manufacturer In Jaipur where I always see the transformers around me. Always curious to know about them.

    ReplyDelete

Post a Comment

Popular posts from this blog

PARTS OF A POWER TRANSFORMER

What are the name of the basic parts of a Power Transformer? We can not deny the fact that only a handful of electrical engineering students are presently familiar with power transformers especially on what it looks like. Unlike a transformer we found in our homes, a power transformer’s appearance and construction is somewhat more complicated. It is not just a simple winding with a primary and secondary terminal although basically any transformer has one. The function that a power transformer plays in an electrical system is very important that an electric utility can not afford to loss it during its operation. Our discussion here will focus more on the basic parts and functions of a power transformer that are usually tangible whenever you go to a substation . Although not all power transformers are identical, nonetheless they all have the following listed parts in which the way of construction may differ.

ELECTRIC MOTOR FRAME SIZE STANDARD SPECIFICATIONS

ELECTRIC MOTOR FRAME SIZE STANDARD SPECIFICATIONS How is electric motor frame size being specified? Motor frame dimensions have been standardized with a uniform frame size numbering system. This system was developed by NEMA and specific frame sizes have been assigned to standard motor ratings based on enclosure, horsepower and speed. The current standardized frames for integral horsepower induction motors ranges from 143T to 445T. These standards cover most motors in the range of one through two hundred horsepower. Typical example of where you can locate the frame is shown in Fig 1.2.D – Frame No. The numbers used to designate frame sizes have specific meanings based on the physical size of the motor. Some digits are related to the motor shaft height and the remaining digit or digits relate to the length of the motor. The rerate, or frame size reduction programs were brought about by advancements in motor technology relating mainly to higher temperature ratings of insulating mate...

ELECTRIC MOTOR NAMEPLATE SPECIFICATIONS

How do we interpret an electric motor nameplate? Motor standards are established on a country by country basis.Fortunately though, the standards can be grouped into two major categories: NEMA and IEC (and its derivatives). In North America, the National Electric Manufacturers Association (NEMA) sets motor standards, including what should go on the nameplate (NEMA Standard MG 1-10.40 "Nameplate Marking for Medium Single-Phase and Polyphase Induction Motors").